![]() A RAID 6 virtual drive can survive two failed drives. ![]() If a single drive in a RAID 1, RAID 5, RAID 10, or RAID 50 virtual drive fails, the system is protected from data loss. To open this window, select Manage > Show Progress. You can monitor the progress of drive rebuilds in the Group ShowProgress window. The rebuild is a fully automatic process, so it is not necessary to issue a Rebuild command. If a drive in a redundant virtual drive (RAID 1, 5, 6, 10, 50, or 60) fails, the MegaRAID Storage Manager software automatically rebuilds the data on a hot spare drive to prevent data loss. The full manual can be found on the LSI website ( ) or click here to go directly to the manual. The following article is an extract of the MegaRAID Storage Manager software manual.